Q1: What is the address of Tritech Disconnectors (Ind) Pvt.Ltd.?
A1: The address of Tritech Disconnectors (Ind) Pvt.Ltd. is 1st Floor, Gajra Chambers, Kamod Nagar, Opposite HDFC Bank, Mumbai Agra Highway, Nashik – 422009, Maharashtra, India.
Q2: What type of products does Tritech Disconnectors (Ind) Pvt.Ltd. manufacture?
A2: Tritech Disconnectors (Ind) Pvt.Ltd. manufactures isolators and disconnectors, which are mechanically operated safety devices used for electrical isolation of systems.
Q3: In what industry is Tritech Disconnectors (Ind) Pvt.Ltd. operating?
A3: Tritech Disconnectors (Ind) Pvt.Ltd. operates in the electrical industry, specifically in high voltage installations, transmission and distribution layouts.
Q4: What are the services offered by Tritech Disconnectors (Ind) Pvt.Ltd.?
A4: The company offers supply of products, infrastructure development, and other services as mentioned on their website.
Q5: How can one contact Tritech Disconnectors (Ind) Pvt.Ltd.?
A5: One can contact Tritech Disconnectors (Ind) Pvt.Ltd. through phone at (+91) 253 2327468 / 69 or email at tritech.corp@gmail.com, or through their career page at tritechcorporation.hr@gmail.com.
Q6: What is the distance between Shirdi International Airport and Tritech Disconnectors (Ind) Pvt.Ltd.?
A6: The distance between Shirdi International Airport and Tritech Disconnectors (Ind) Pvt.Ltd. is 85 km.
Q7: What are the different types of isolators manufactured by Tritech Disconnectors (Ind) Pvt.Ltd.?
A7: The company manufactures six types of isolators: Banging Type, Turn & Twist Type, Horizontal Double Break (HDB), Vertical Single Break (VSB), Horizontal Single Break (HSB), and HDB with UNDERHUNG Banging Type.
Q8: What is the STC value for each type of isolator?
A8: The STC values for each type of isolator are as follows:
Banging Type: 11 kV 13.1 kA for 3 seconds
Turn & Twist Type: 33 kV 31.5 kA for 3 seconds, 66 kV 40 kA for 3 seconds, 132 kV 40 kA for 3 seconds, 220 kV 40 kA for 3 seconds, and 400 kV 40 KA for 3 seconds
Horizontal Double Break (HDB): 11 kV 13.1 kA for 3 seconds, 33 kV 31.5 kA for 3 seconds, 66 kV 40 kA for 3 seconds, 132 kV 40 kA for 3 seconds, and 220 kV 40 kA for 3 seconds
Vertical Single Break (VSB): 11 kV 13.1 kA for 3 seconds, 33 kV 26.5 kA for 3 seconds, 66 kV 40 kA for 3 seconds, 132 kV 40 kA for 3 seconds, and 220 kV 40 kA for 3 seconds
Horizontal Single Break (HSB): 11 kV 13.1 kA for 3 seconds, 33 kV 26.5 kA for 3 seconds, 66 kV 40 kA for 3 seconds, 132 kV 40 kA for 3 seconds, and 220 kV 40 kA for 3 seconds
HDB with UNDERHUNG Banging Type: 11 kV 13.1 kA for 3 seconds, 33 kV 31.5 kA for 3 seconds, 66 kV 40 kA for 3 seconds, 132 kV 40 kA for 3 seconds, and 220 kV 40 kA for 3 seconds